Shanghai Orsin Medical Technology Co., Ltd. miaomiao8615@orsins.com 86-021-57450666
Shanghai Orsin Medical Technology Co., Ltd. Profil Perusahaan
Produk
Rumah > Produk > Tabung Uji Darah Vakum > High Productivity 12000pcs/hour Vacuum Blood Test Tube with Superior Serum Yield and Customized Pipe Size for ESR Testing

High Productivity 12000pcs/hour Vacuum Blood Test Tube with Superior Serum Yield and Customized Pipe Size for ESR Testing

Rincian produk

Tempat asal: CINA

Nama merek: Orsin

Sertifikasi: ISO 13485

Nomor model: Aktivator Gel Clot

Syarat Pembayaran & Pengiriman

Kuantitas min Order: 100/pcs

Harga: dapat dinegosiasikan

Waktu pengiriman: 1-4 minggu

Syarat-syarat pembayaran: L/C, D/A, D/P, T/T, Western Union

Menyediakan kemampuan: 20 juta/pcs/ngengat

Dapatkan Harga Terbaik
bicara sekarang
Rincian produk
Menyoroti:

12000pcs/hour Productivity Vacuum Blood Test Tube

,

Superior Serum Yield ESR Blood Collection Tube

,

Customized Pipe Size Sodium Citrate Tube

Fitur:
Hasil serum superior
Ukuran tabung:
Ukuran pipa yang disesuaikan
Produktivitas:
12000pcs/jam
Bentuk antikoagulan:
Sodium atau garam lithium
Jenis penutupan:
Stopper karet
Tube Stopper:
Karet
Waktu tunggu:
1-4 minggu
Warna:
transparan
Tutup tabung:
Gelas plastik
Label tabung:
Kertas
Bahan pengemasan:
Hewan peliharaan/kaca
Pabrikan:
Shanghai Orsin Medical Technology Co.ltd
Bahan penutupan:
Stopper karet sintetis
ciri:
Biopsi cair
Fitur:
Hasil serum superior
Ukuran tabung:
Ukuran pipa yang disesuaikan
Produktivitas:
12000pcs/jam
Bentuk antikoagulan:
Sodium atau garam lithium
Jenis penutupan:
Stopper karet
Tube Stopper:
Karet
Waktu tunggu:
1-4 minggu
Warna:
transparan
Tutup tabung:
Gelas plastik
Label tabung:
Kertas
Bahan pengemasan:
Hewan peliharaan/kaca
Pabrikan:
Shanghai Orsin Medical Technology Co.ltd
Bahan penutupan:
Stopper karet sintetis
ciri:
Biopsi cair
Deskripsi Produk

Function:

  1. AnticoagulationThe black-top tube employs a 0.129mol/L sodium citrate buffer system to anticoagulate blood specimens. Applicable for inflammatory disease monitoring. Advantages: unique value compared to modern inflammatory markers.

  2. 1. Monitoring Inflammatory Diseases

Condition Clinical Utility
Infections Bacterial TB → ESR ↑↑ >100 mm/h
Autoimmune diseases Active RA → ESR ↑ (combined with CRP)
Malignancies Multiple myeloma → Persistent ESR ↑ (therapy monitor)

2. Procedure (ICSH Protocol)

  1. Fill blood to the calibration mark → 2. Invert mix 8 times → 3. Place vertically in Westergren rack → 4. Stand undisturbed at RT for 60 min → 5. Measure plasma interface drop (mm) = ESR value.

3. Result Interpretation

ESR (mm/h) Clinical Implication
<20 (M) / <30 (F) Normal
20–50 Mild elevation (e.g., chronic inflammation)
>50 Significant elevation (active infection/tumor)

1. Error Control

  • Fill volume deviation:

    ±10% error → ESR deviation up to 30% (Must fill exactly to the mark!).ect.

     

    2. Interfering Factors

Factor ESR Effect Solution
Anemia (Hct<30%) Falsely ↑ Corrected ESR = ESR × [0.73+Hct]
Refrigerated sample Falsely ↓ Equilibrate to RT for 30 min
Underfilled tube Clot formation Discard and recollect