Shanghai Orsin Medical Technology Co., Ltd. miaomiao8615@orsins.com 86-021-57450666
Product Details
Place of Origin: Shanghai, China
Brand Name: Orsin
Certification: ISO 13485
Model Number: Gel Clot Activator
Payment & Shipping Terms
Minimum Order Quantity: 30000 PCS
Price: Negotiation
Delivery Time: 1-4 weeks
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Merit: |
Enhanced Sample Stability |
Capacity: |
Can Be Customized |
Key Features: |
Rapid Clotting |
Material: |
High-clarity PET Plastic |
Tube Diameter: |
13 × 75mm (standard) / 13 × 100mm (large) |
Closure Material: |
Synthetic Rubber Stopper |
Merit: |
Enhanced Sample Stability |
Capacity: |
Can Be Customized |
Key Features: |
Rapid Clotting |
Material: |
High-clarity PET Plastic |
Tube Diameter: |
13 × 75mm (standard) / 13 × 100mm (large) |
Closure Material: |
Synthetic Rubber Stopper |
Orsin Medical Technology – Gel & Clot ActivatorExtraction & Analysis Solutions
1. Product Description
Orsin Medical Technology presents our advanced Gel & Clot Activator Blood Collection Tubes, engineered to deliver superior serum separation for modern diagnostic laboratories. Our innovative vacuum blood collection system combines optimal clot activation with intelligent gel separation technology to ensure specimen integrity from collection to analysis.
Parameter | Specification Details | Testing Method/Standard |
---|---|---|
Tube Characteristics | ||
Material | High-clarity PET plastic | ASTM D4601 |
Tube Diameter | 13 × 75mm (standard) / 13 × 100mm (large) | ISO 6710 |
Closure Material | Synthetic rubber stopper | USP Class VI |
Draw Volume Accuracy | ±5% of nominal volume | CLSI H3-A6 |
Vacuum Stability | Maintains vacuum for 24 months at 4-25°C | In-house stability testing |
| Clot Activator | | |
| Type | Silica particles (micronized) | SEM analysis |
| Surface Area | 5-8 m²/g | BET method |
| Concentration | 6.0±0.5 mg/mL blood | Gravimetric analysis |
| Clotting Time | 15-25 minutes at room temperature | Visual clot observation |
| Separation Gel | | |
| Composition | Thixotropic polyester gel | FTIR spectroscopy |
| Density | 1.04±0.01 g/cm³ | Pycnometer |
| Gel Stability Temperature| 2-30°C (maintains viscosity) | Rheological testing |
| Barrier Formation | Complete within 10 minutes at 1300 RCF | Visual inspection |
| Performance | | |
| Centrifugation Conditions| 1300-2000 RCF for 10 minutes | CLSI H21-A5 |
| Serum Yield | ≥95% of available serum | Gravimetric measurement |
| Hemolysis Rate | <0.5% (visual assessment scale) | Spectrophotometric method |
| Interference Testing | Non-interference with common chemistry assays | CLSI EP07 |
| Quality Standards | | |
| Sterilization | Gamma irradiation (25-40 kGy) | ISO 11137 |
| Endotoxin Level | <0.5 EU/mL | LAL test |
| Biocompatibility | USP Class VI compliant | ISO 10993 |
| Shelf Life | 24 months from manufacture | Accelerated stability testing |
3,Performance Advantages by Application:
For trace element analysis: Ultra-pure tube materials prevent metal contamination
For molecular testing: Provides high-quality serum for PCR-based assays
For point-of-care testing: Ensures sample stability during transport
Compatibility Notes:
Validated for use with major automated platforms (Roche Cobas, Siemens Advia, Abbott Architect)
Suitable for both ELISA and chemiluminescence methodologies
Recommended for high-sensitivity assays (hs-CRP, hs-Troponin)
This comprehensive application guide demonstrates the tubes' versatility across:
Routine hospital laboratories
Reference laboratories
Research institutions
Public health programs
Parameter | Specification |
---|---|
Clotting Time | 20–30 minutes (at room temperature) |
Gel Stability | Maintains separation at 1,500–2,000 RCF |
Centrifugation | 10–15 minutes at 1,200–1,500 × g |
Sample Volume | 3 mL, 5 mL, 10 mL (standard sizes) |
Tube Material | PET plastic, safety-engineered closure |
Shelf Life | 24 months (under recommended storage) |
Additive | Silica-based clot activator + inert gel |