Shanghai Orsin Medical Technology Co., Ltd. miaomiao8615@orsins.com 86-021-57450666
Shanghai Orsin Medical Technology Co., Ltd. Şirket Profili
Ürünler
Evde > Ürünler > Vakumlu kan testi tüpü > Enhanced Stability Lithium Heparin Tube with Reversible Anticoagulation for Plasma Separation in 13 × 75mm and 13 × 100mm Sizes

Enhanced Stability Lithium Heparin Tube with Reversible Anticoagulation for Plasma Separation in 13 × 75mm and 13 × 100mm Sizes

Ürün Ayrıntıları

Menşe yeri: ÇİN

Marka adı: Orsin

Sertifika: ISO 13485

Model numarası: Jel pıhtı aktivatörü

Ödeme ve Nakliye Şartları

Min sipariş miktarı: 100/PCS

Fiyat: pazarlık edilebilir

Teslim süresi: 1-4 hafta

Ödeme koşulları: L/C, D/A, D/P, T/T, Western Union

Yetenek temini: 20 milyon/PC/Güve

En İyi Fiyatı Alın
Şimdi konuşalım.
Ürün Ayrıntıları
Vurgulamak:

Reversible Anticoagulation Lithium Heparin Tube

,

13 × 75mm Plasma Separation Tube

,

13 × 100mm Vacuum Blood Collection Tube

Logo baskısı:
Büyük Siparişler için kullanılabilir (> 30000 PC)
Trombosit aktivitesi:
İstikrar onaylandı
Anahtar Özellikler:
Hızlı pıhtılaşma
Ambalaj malzemesi:
Evcil hayvan/cam
Ürün Nam:
DNA
Depolama koşulu:
Oda sıcaklığı
Pıhtılaşan:
Orsin'e özgü pıhtılaşan
Avantajlar:
Gelişmiş istikrar
Üstünlük:
Hücre koruması
Kapanma malzemesi:
Sentetik kauçuk tıpa
Tüp çapı:
13 × 75mm / 13 × 100mm
Otomatik boru:
Evet
Üretim deneyimi:
14 yıldan fazla
Logo baskısı:
Büyük Siparişler için kullanılabilir (> 30000 PC)
Trombosit aktivitesi:
İstikrar onaylandı
Anahtar Özellikler:
Hızlı pıhtılaşma
Ambalaj malzemesi:
Evcil hayvan/cam
Ürün Nam:
DNA
Depolama koşulu:
Oda sıcaklığı
Pıhtılaşan:
Orsin'e özgü pıhtılaşan
Avantajlar:
Gelişmiş istikrar
Üstünlük:
Hücre koruması
Kapanma malzemesi:
Sentetik kauçuk tıpa
Tüp çapı:
13 × 75mm / 13 × 100mm
Otomatik boru:
Evet
Üretim deneyimi:
14 yıldan fazla
Ürün Tanımı

Product Description: Enhanced Stability Lithium Heparin Tube (Rapid & Reversible)

The Enhanced Stability Lithium Heparin Tube (Rapid & Reversible) is a high-performance vacuum blood collection tube engineered to optimize pre-analytical specimen quality for clinical chemistry and immunology testing. As a lithium heparin-coated tube—widely recognized for its role as an anticoagulant in plasma separation—it integrates two key technological upgrades: rapid-action activation and reversible anticoagulation properties, delivering superior sample stability compared to conventional heparin tubes.
Its rapid-action design ensures the lithium heparin coating is immediately and uniformly activated upon blood entry, accelerating anticoagulation to prevent early clot formation within seconds. This minimizes the risk of sample degradation caused by delayed anticoagulation, a common issue in time-sensitive tests. The tube’s unique reversible feature further allows for flexible post-collection processing: if needed, the anticoagulant effect can be neutralized under controlled conditions, enabling additional downstream analyses that require coagulated samples—expanding the tube’s utility beyond standard heparin tubes.
Designed to enhance sample stability, this tube maintains the integrity of analytes (e.g., electrolytes, enzymes, hormones) for extended periods at both room temperature and refrigerated storage, ensuring consistent and reliable test results even in busy clinical laboratories or during transportation. Available in standard sizes (13×75mm, 13×100mm, 16×100mm) to accommodate diverse blood volume requirements, it is compatible with standard blood collection systems and automated analyzers, streamlining lab workflows.
Ideal for hospitals, diagnostic centers, and research laboratories, the Enhanced Stability Lithium Heparin Tube (Rapid & Reversible) combines the proven performance of lithium heparin with innovative features to address critical pre-analytical challenges, supporting accurate clinical diagnosis and efficient lab operations.

Key Characteristics Highlighting its Function:

  • Rapid Action: Heparin acts quickly upon mixing with blood, providing immediate anticoagulation.

  • Reversible (in theory): While not routinely done in clinical labs, heparin's effect can be countered by substances like protamine sulfate. This reversibility is sometimes relevant in specific therapeutic contexts, but not typically for sample collection tubes.

  • Ideal for Chemistry: The use of Lithium salt minimizes interference, particularly crucial for accurate measurement of:

    • Electrolytes: Sodium (Na+), Potassium (K+), Chloride (Cl-), Lithium (Li+ - though less common), Bicarbonate (HCO3-)

    • Renal/Liver Function Markers: Urea, Creatinine, Uric Acid, Bilirubin, Liver Enzymes (ALT, AST, ALP, GGT)

    • Metabolites: Glucose, Lactate

    • Hormones: Many hormone assays

    • Therapeutic Drug Monitoring (TDM): For various drugs

    • Enzymes: Amylase, Lipase, CK

  • Not Suitable for All Tests: Importantly, Lithium Heparin tubes are NOT appropriate for:

    • Coagulation/Haemostasis Tests: (e.g., PT, APTT, Fibrinogen) - Heparin directly interferes with these tests. Citrate tubes (like light blue top) are used instead.

    • Blood Smears/Morphology: Heparin can cause staining artifacts. EDTA tubes (purple/lavender top) are preferred for hematology.

    • Some Immunology/Serology Tests: Depending on the specific assay, serum (from clot activator tubes) or EDTA plasma might be required.

    • Trace Metal Analysis (Lithium): Obviously not suitable if lithium levels are being measured.

In Summary:

The primary and indispensable function of Lithium Heparin is to effectively prevent blood clotting in collection tubes by enhancing antithrombin activity, thereby enabling the reliable collection of plasma samples. Its key advantage lies in the use of lithium as the counter-ion, which minimizes interference with a broad spectrum of routine clinical chemistry analytes, particularly electrolytes, making it the workhorse anticoagulant for general biochemistry testing in modern clinical laboratories.