Shanghai Orsin Medical Technology Co., Ltd. miaomiao8615@orsins.com 86-021-57450666
Shanghai Orsin Medical Technology Co., Ltd. Profil d'entreprise
produits
Maison > produits > Tuyaux de test sanguin sous vide > Prothrombin Time Tube with Composite Antimony System Technology and Bionic Active Membrane for Enhanced Sample Stability

Prothrombin Time Tube with Composite Antimony System Technology and Bionic Active Membrane for Enhanced Sample Stability

Détails de produit

Lieu d'origine: Chine

Nom de marque: Orsin

Certification: ISO 13485

Numéro de modèle: Activateur de caillot de gel

Conditions de paiement et d'expédition

Quantité de commande min: 100 / PCS

Prix: négociable

Délai de livraison: 1 à 4 semaines

Conditions de paiement: LC, D/A, D/P, T/T, Western Union

Capacité d'approvisionnement: 20 millions / PC / Moth

Obtenez le meilleur prix
Causez Maintenant
Détails de produit
Mettre en évidence:

Composite Antimony System Technology Prothrombin Time Tube

,

Bionic Active Membrane Prothrombin Time Tube

,

Screw Cap Prothrombin Time Tube

Types de matériaux:
Animal de compagnie
Scénarios d'application:
Biopsie liquide
Exemple de commande:
Disponible
Mérite:
Stabilité de l'échantillon amélioré
Caractéristiques:
Excellente stabilité
Système anticoagulant:
Technologie du système d'antimoine composite
Activité plaquettaire:
Stabilité confirmée
Date d'expiration:
Imprimé sur le Tube
Limite MOQ:
18000 à 200000 pièces
Usage:
Collection et stockage de sang
Propriétés:
Durable et fiable
Traitement du mur intérieur:
Membrane active bionique
Type de capuchon de tube:
Bouchon à vis
Types de matériaux:
Animal de compagnie
Scénarios d'application:
Biopsie liquide
Exemple de commande:
Disponible
Mérite:
Stabilité de l'échantillon amélioré
Caractéristiques:
Excellente stabilité
Système anticoagulant:
Technologie du système d'antimoine composite
Activité plaquettaire:
Stabilité confirmée
Date d'expiration:
Imprimé sur le Tube
Limite MOQ:
18000 à 200000 pièces
Usage:
Collection et stockage de sang
Propriétés:
Durable et fiable
Traitement du mur intérieur:
Membrane active bionique
Type de capuchon de tube:
Bouchon à vis
Description de produit

Product Description

  1. A specialized prothrombin time (PT) testing system comprising blood collection tubes and an INR (International Normalized Ratio) calibration foundation, engineered to deliver accurate, standardized results when used with automated analyzers.
  2. This integrated PT tube and INR normalization base is optimized for seamless compatibility with automated diagnostic equipment, ensuring consistent activation of coagulation factors and precise calculation of INR values—critical for monitoring anticoagulant therapy.
  3. Designed for clinical laboratories, the product combines a clot-activator-coated PT tube with a validated INR reference foundation, streamlining prothrombin time testing while meeting international standards for automated analyzer performance.

Core Mechanism

  1. 3.2% Sodium Citrate

    • Precise chelation of calcium ions (Ca²⁺), inhibiting coagulation cascade

    • *Critical ratio control: Anticoagulant:Blood=1:9*

    • *>10% deviation causes falsely prolonged PT/APTT*

  1. Automated Analyzer Compatibility: Pre-calibrated to integrate with 主流自动化凝血分析仪(mainstream automated coagulation analyzers), reducing manual intervention and minimizing measurement errors.
  2. INR Standardization: The built-in normalization foundation ensures results align with international INR benchmarks, enabling consistent comparisons across laboratories and testing platforms.
  3. Optimized Coagulation Activation: PT tubes feature uniform coating of clot activators, promoting rapid, stable clot formation—ideal for timely prothrombin time analysis.

Core Applications

Test Panel Clinical Significance
PT (Prothrombin Time) Warfarin monitoring/Liver function
APTT (Activated Partial Thromboplastin Time) Heparin therapy/Intrinsic pathway
Coagulation Factor Assays Hemophilia diagnosis

Critical Warnings

⚠️

  • Underfilling (90% volume): PT prolongation ≥20% (may cause false heparin resistance)

⚠️

  • *Gently invert 5-8 times immediately (vigorous shaking activates platelets)*

Automated Integration Excellence

  • Seamless hardware-software synergy with automated analyzers eliminates manual calibration steps, reducing inter-operator variability by up to 30% compared to conventional systems.
  • Proprietary interface design ensures real-time data synchronization with mainstream coagulation analyzers (e.g., Sysmex, Stago), cutting assay setup time by 40%.

2. INR Standardization Precision

  • Embedded with WHO-certified reference calibrators, the normalization foundation achieves INR result consistency within ±0.1 across different testing platforms, exceeding CLIA proficiency standards.
  • Advanced matrix-matching technology minimizes matrix effects between the PT tube’s additive and patient samples, ensuring INR values remain stable even with hemolyzed or lipemic specimens