Shanghai Orsin Medical Technology Co., Ltd. miaomiao8615@orsins.com 86-021-57450666
Shanghai Orsin Medical Technology Co., Ltd. Unternehmensprofil
produits
Haus > produits > Vakuum-Blutprüfrohr > Prothrombin Time Tube with Composite Antimony System Technology and Bionic Active Membrane for Enhanced Sample Stability

Prothrombin Time Tube with Composite Antimony System Technology and Bionic Active Membrane for Enhanced Sample Stability

Produktdetails

Herkunftsort: China

Markenname: Orsin

Zertifizierung: ISO 13485

Modellnummer: Gel -Gerinnselaktivator

Zahlungs-u. Verschiffen-Ausdrücke

Min Bestellmenge: 100/PCs

Preis: verhandelbar

Lieferzeit: 1-4 Wochen

Zahlungsbedingungen: L/C, D/A, D/P, T/T, Western Union

Versorgungsmaterial-Fähigkeit: 20 Millionen/PCs/Motte

Erhalten Sie besten Preis
Plaudern Sie Jetzt
Produktdetails
Hervorheben:

Composite Antimony System Technology Prothrombin Time Tube

,

Bionic Active Membrane Prothrombin Time Tube

,

Screw Cap Prothrombin Time Tube

Materialtypen:
Haustier/Glas
Anwendungsszenarien:
Flüssigbiopsie
Probenreihenfolge:
Verfügbar
Verdienst:
Verbesserte Probenstabilität
Merkmal:
Hervorragende Stabilität
Antikoagulans System:
Zusammengesetzte Antimon -Systemtechnologie
Thrombozytenaktivität:
Stabilität bestätigt
Verfallsdatum:
Auf der Tube gedruckt
MOQ -Grenze:
18000-20000 Stück
Verwendung:
Blut-Sammlung und Speicher
Eigenschaften:
Langlebig und zuverlässig
Innenwandbehandlung:
Bionische aktive Membran
Rohrkappenentyp:
Schraubenkappe
Materialtypen:
Haustier/Glas
Anwendungsszenarien:
Flüssigbiopsie
Probenreihenfolge:
Verfügbar
Verdienst:
Verbesserte Probenstabilität
Merkmal:
Hervorragende Stabilität
Antikoagulans System:
Zusammengesetzte Antimon -Systemtechnologie
Thrombozytenaktivität:
Stabilität bestätigt
Verfallsdatum:
Auf der Tube gedruckt
MOQ -Grenze:
18000-20000 Stück
Verwendung:
Blut-Sammlung und Speicher
Eigenschaften:
Langlebig und zuverlässig
Innenwandbehandlung:
Bionische aktive Membran
Rohrkappenentyp:
Schraubenkappe
Produkt-Beschreibung

Product Description

  1. A specialized prothrombin time (PT) testing system comprising blood collection tubes and an INR (International Normalized Ratio) calibration foundation, engineered to deliver accurate, standardized results when used with automated analyzers.
  2. This integrated PT tube and INR normalization base is optimized for seamless compatibility with automated diagnostic equipment, ensuring consistent activation of coagulation factors and precise calculation of INR values—critical for monitoring anticoagulant therapy.
  3. Designed for clinical laboratories, the product combines a clot-activator-coated PT tube with a validated INR reference foundation, streamlining prothrombin time testing while meeting international standards for automated analyzer performance.

Core Mechanism

  1. 3.2% Sodium Citrate

    • Precise chelation of calcium ions (Ca²⁺), inhibiting coagulation cascade

    • *Critical ratio control: Anticoagulant:Blood=1:9*

    • *>10% deviation causes falsely prolonged PT/APTT*

  1. Automated Analyzer Compatibility: Pre-calibrated to integrate with 主流自动化凝血分析仪(mainstream automated coagulation analyzers), reducing manual intervention and minimizing measurement errors.
  2. INR Standardization: The built-in normalization foundation ensures results align with international INR benchmarks, enabling consistent comparisons across laboratories and testing platforms.
  3. Optimized Coagulation Activation: PT tubes feature uniform coating of clot activators, promoting rapid, stable clot formation—ideal for timely prothrombin time analysis.

Core Applications

Test Panel Clinical Significance
PT (Prothrombin Time) Warfarin monitoring/Liver function
APTT (Activated Partial Thromboplastin Time) Heparin therapy/Intrinsic pathway
Coagulation Factor Assays Hemophilia diagnosis

Critical Warnings

⚠️

  • Underfilling (90% volume): PT prolongation ≥20% (may cause false heparin resistance)

⚠️

  • *Gently invert 5-8 times immediately (vigorous shaking activates platelets)*

Automated Integration Excellence

  • Seamless hardware-software synergy with automated analyzers eliminates manual calibration steps, reducing inter-operator variability by up to 30% compared to conventional systems.
  • Proprietary interface design ensures real-time data synchronization with mainstream coagulation analyzers (e.g., Sysmex, Stago), cutting assay setup time by 40%.

2. INR Standardization Precision

  • Embedded with WHO-certified reference calibrators, the normalization foundation achieves INR result consistency within ±0.1 across different testing platforms, exceeding CLIA proficiency standards.
  • Advanced matrix-matching technology minimizes matrix effects between the PT tube’s additive and patient samples, ensuring INR values remain stable even with hemolyzed or lipemic specimens